Published November 1, 1999 | Version v1
Report Restricted

NSTX Filament Preionization and Glow Discharge Cleaning Systems

Description

Initial NSTX GDC experiments were performed with one moveable anode and a biased filament preionization system that allowed D2 and He Glow Discharge breakdowns at the actual operating pressure, voltage and current. The biased filament system was also operated continuously during ohmic operations, and used to reduce volt-sec consumption for February 1999 plasma discharges up to 280 KA. An upgraded system has been installed with 2 fixed wall anodes and 3 biased filaments; 2 on the mid-plane and one in the divertor region; all separately controllable remotely using a PLC system. Recent applications include assisting in preionization for 800 KA plasma discharges

Availability note (English)

Available from INIS in electronic form; Also available from OSTI as DE00014466; PURL: https://www.osti.gov/servlets/purl/14466-DKMTuU/webviewable/

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
4 p.
Report number
PPPL--3381

Optional Information

Contract/Grant/Project number
AC02-76CH03073
Funding organization
USDOE Office of Energy Research (ER) (United States)