Published February 1998 | Version v1
Journal article

Duoplasmatron source modifications for 3He+ operation

  • 1. Fermi National Accelerator Laboratory, MS 307, Batavia, Illinois 60510 (United States)

Description

A duoplasmatron ion source is used to produce 25 mA of 3He+ with a pulse width of ∼80ms at 360 Hz for acceleration to 10.5 MeV. At this energy, 3He striking water or carbon targets can produce short lived isotopes of 11C, 13N, 15O, and 18F for medical positron emission tomography (PET). A duoplasmatron ion source was chosen originally since it is capable of a sufficient singly charged helium beam with an acceptable gas consumption. Stable long-term operation of the source required a change in the filament material to molybdenum, and a careful understanding of the oxide filament conditioning, operation and geometry. Other improvements, particularly in the electronics, were helpful to increasing the reliability. The source has operated for many months at ∼2.5% duty factor without significant problems and with good stability. We report here the effort that was done to make this source understandable and reliable

Additional details

Publishing Information

Journal Title
Review of Scientific Instruments
Journal Volume
69
Journal Issue
2
Journal Page Range
p. 1020-1022
ISSN
0034-6748
CODEN
RSINAK

Conference

Title
7. international conference on ion sources
Dates
26-27 Jan 1998
Place
Shirahama (Japan)

Optional Information

Secondary number(s)
CONF-980145--