Published March 1, 2018 | Version v1
Journal article

Efficiency assessment of bi-radiated screens and improved convective set of tubes during the modernization of PTVM-100 tower hot-water boiler based on controlled all-mode mathematic models of boilers on Boiler Designer software

  • 1. Heat Power Plants department, Non-profit JSC "Almaty University of Power Engineering and Telecommunications", 050013 Almaty (Kazakhstan)

Description

This work contains analysis of technical values of tower hot-water boiler PTVM-100 when operating on gas and oil residual. After the test it became clear that due to the construction deficiency during the combustion of oil residual, it is not possible to provide long-term production of heat. There is also given a short review on modernization of PTVM-100 hot-water boilers. With the help of calculations based on controlled all-mode mathematic modules of hot-water boilers in BOILER DESIGNER software, it was shown that boiler modernization by use of bi-radiated screens and new convective set of tubes allows decreasing sufficiently the temperature of combustor output gases and increase reliability of boiler operation. Constructive changes of boiler unit suggested by authors of this work, along with increase of boiler's operation reliability also allow to improve it's heat production rates and efficiency rate up to 90,5% when operating on fuel oil and outdoor installation option. (paper)

Availability note (English)

Available from http://dx.doi.org/10.1088/1755-1315/136/1/012016

Additional details

Publishing Information

Journal Title
IOP Conference Series: Earth and Environmental Science (Online)
Journal Volume
136
Journal Issue
1
Journal Page Range
[10 p.]
ISSN
1755-1315

Conference

Title
6. International Conference on Power Science and Engineering
Acronym
ICPSE 2017
Dates
2-4 Dec 2017
Place
St. Petersburg (Russian Federation)