Published 1993
| Version v1
Report
Physics requirements of Commissioning diagnostics for SSCL linac
Creators
- 1. Superconducting Super Collider Lab., Dallas, TX (United States)
- 2. Allied Signal, Kansas City, MO (United States)
Description
Commissioning diagnostics are described in terms of the beam physics requirements of the SSCL linac. Commissioning diagnostics include current monitors, beam position monitors, spectrometer, foil scattering experiment, wire scanners, Faraday cups, and bunch shape monitors. Two DOE integrated contractors, the Superconducting Super Collider Laboratory and Allied Signal, Kansas City Plant, are developing the commissioning diagnostics. The need to measure bright, short linac beam pulses requires special design considerations. High density harps and collectors with up to 50 wires per cm and 128 wires total, and fast, 3.5-MHz amplifiers have been developed. The diagnostics will be first used and tested during beam commissioning of the RFQ
Additional details
Publishing Information
- Imprint Title
- Proceedings of the 1993 Particle Accelerator Conference: Volume 3
- Imprint Pagination
- 970 p.
- Journal Page Range
- p. 2124-2126.
- Report number
- DOE/ER/40779--1-Vol.3
Conference
- Title
- international particle accelerator conference.
- Acronym
- PAC '93
- Dates
- 17-20 May 1993.
- Place
- Washington, DC (United States).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 26025397
- Subject category
- S43: PARTICLE ACCELERATORS; S42: ENGINEERING;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- DESIGN; ION BEAMS; MEASURING INSTRUMENTS; QUADRUPOLE LINACS; SPECIFICATIONS; SUPERCONDUCTING SUPER COLLIDER
- Descriptors DEC
- ACCELERATORS; BEAMS; CYCLIC ACCELERATORS; LINEAR ACCELERATORS; STORAGE RINGS; SYNCHROTRONS
Optional Information
- Contract/Grant/Project number
- Contract AC35-89ER40486
- Secondary number(s)
- CONF-930511--Vol.3.