Published April 1993 | Version v1
Journal article

A UK analysis of light gas distribution experiment E11.2 in the HDR facility

  • 1. Reactor Safety Studies Dept., Safety and Performance Div., AEA Reactor Services, Winfrith Technology Centre, Dorchester (United Kingdom)

Description

The HDR facility is a large-scale containment building which is highly compartmentalised except for the upper dome region. The E11.2 experiment in HDR began with a simulated small-break LOCA, followed by a period of light gas injection. The CONTAIN 1.11 code was used in the UK to analyse this test. The predicted pressure history is shown to be in good agreement with the measurements, however, the degree of thermal and compositional stratification within thhe containment was underestimated. Uncertainties in instrument cooler power distribution and difficulty in precisely estimating flowpath resistance coefficients in such a complex geometry can contribute to such discrepancies. In addition, it is shown that much of the discrepancy may arise from the inability to accurately predict certain types of flows within a single physical volume with the kind of engineering flow equations used in the code. (orig.)

Additional details

Publishing Information

Journal Title
Nuclear Engineering and Design
Journal Volume
140
Journal Issue
1
Journal Page Range
p. 61-68.
ISSN
0029-5493
CODEN
NEDEAU