Published 1983 | Version v1
Book

Determination of pressure carrying capability of the containment structural system for the Mark III standard plant

  • 1. General Electric Co., San Jose, CA (USA). Nuclear Power System Engineering Dept.

Description

As a result of a study of the Three Mile Esland event, and concerns expressed regarding hydrogen control and containment integrity, there is a need to know the capability of the Mark III containment structural system of the current Boiling Water Reactor (BWR) Standard Plant in resisting potentially-high pressure associated with severe but improbable accidents. This paper presents the assessment performed at General Electric to determine the maximum pressure at which the Mark III Containment Structural System can be expected to maintain its integrity. The assessment shows that the pressure that may cause loss of containment integrity at the dome/knuckle region is conservatively calculated to be 58.5 psig which is about four times the design pressure. (orig.)

Additional details

Publishing Information

Publisher
North-Holland.
Imprint Place
Amsterdam (Netherlands)
ISBN
0444 86697 3
Imprint Title
Transactions of the 7. international conference on structural mechanics in reactor technology. Vol. J
Imprint Pagination
543 p.
Journal Page Range
p. 81-88.

Conference

Title
7. international seminar on computational aspects of the finite element method (CAFEM-7) in conjunction with the 7. international conference on structural mechanics in reactor technology (SMIRT-7).
Dates
22-26 Aug 1983.
Place
Chicago, IL (USA).

INIS

Country of Publication
Netherlands
Country of Input or Organization
Netherlands
INIS RN
15049880
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
BWR TYPE REACTORS; CONTAINMENT; DYNAMIC LOADS; PERFORMANCE; PLANNING; STANDARDIZATION
Descriptors DEC
REACTORS; WATER COOLED REACTORS; WATER MODERATED REACTORS

Optional Information

Secondary number(s)
EUR--8596 DE/EN/FR.