Installation and testing of indoor radon reduction techniques in 40 eastern Pennsylvania houses. Final report, October 1984-June 1987
Description
This report discusses the installation and testing of indoor radon-reduction techniques in 40 houses in eastern Pennsylvania. Early in 1985, the Pennsylvania Department of Environmental Resources (PDER) started a large radon survey in communities in the Reading Prong (a granite formation) in eastern Pennsylvania, following the discovery of a house with extremely high radon concentrations, greater than 1.2 MBq/cu m. Candidate houses for the program, with radon concentrations in excess of 750 Bq/cu m, were selected from this survey. A total of 40 houses with representative substructure types were chosen from this group, and mitigation methods were selected and installed from June 1985 to June 1987. Initial soil-ventilation installations achieved large reductions in radon concentrations at low cost, but these reductions were not always sustained in colder weather, and several systems were modified during the project to improve their performance. Major reductions in radon concentration were realized in all the houses worked on, with most houses with active soil ventilation systems achieving less than 150 Bq/cu m (4 pCi/L) on an annual average basis in the living areas
Availability note (English)
Available from NTIS, PC A17/MF A01.
Files
Additional details
Publishing Information
- Imprint Pagination
- 399 p.
- Report number
- PB--88-156617/XAB
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 19082499
- Subject category
- S54: ENVIRONMENTAL SCIENCES;
- Descriptors DEI
- AERATION; AIR POLLUTION; BUILDINGS; CONTROL; MONITORING; RADON 222; SOILS; VENTILATION
- Descriptors DEC
- ALPHA DECAY RADIOISOTOPES; DAYS LIVING RADIOISOTOPES; EVEN-EVEN NUCLEI; HEAVY NUCLEI; ISOTOPES; NUCLEI; POLLUTION; RADIOISOTOPES; RADON ISOTOPES
Optional Information
- Secondary number(s)
- EPA--600/8-88/002.