Published 1983 | Version v1
Journal article

Resolution of a sonic spark chamber applied in a magnetic spectrograph

Description

The spatial resolution of a spark sonic chamber is measured when using a collimated α-source. The estimates of the contribution of multiple scattering in the line width are obtained. It is shown that line broadening is mainly due to multiple scattering of registered particles during their passing of the inlet window and detector gas

Additional details

Additional titles

Original title (Russian)
Разрешение искровой звуковой камеры, используемой в магнитном спектрографе

Publishing Information

Journal Title
Prikl. Yad. Spektrosk.
Journal Issue
no.12
Series
Prikl. Yad. Spektrosk.
ISSN
0370-2715