Outdoor air monitoring: Performance evaluation of a gas sensor to assess episodic nuisance/odorous events using active multi-sorbent bed tube sampling coupled to TD-GC/MS analysis

  • 1. Laboratori del Centre de Medi Ambient, Escola Tècnica Superior d'Enginyeria Industrial de Barcelona (ETSEIB), Universitat Politècnica de Catalunya (LCMA-UPC), Avda. Diagonal, 647, E 08028 Barcelona (Spain)
  • 2. Centres Científics i Tecnològics, Universitat de Barcelona (CCiTUB), Lluís Solé Sabarís 1-3, E 08034 Barcelona (Spain)

Description

Highlights: • Use of a semiconductor gas sensor for activating a sampler during pollution episodes • Simultaneous 24 h and episodic samples were taken during 15 days in El Morell. • Higher levels of VOCs, not specific compounds, trigger the activation of the sampler. • Sensor interferences derived from relative humidity were not observed. • The study proposes an expansion of the field of use of semiconductor gas sensors. -- Abstract: In order to evaluate the performance of a commercially available metal oxide semiconductor gas sensor (TGS 2602, Figaro Engineering Inc.) for activating a monitoring system when a nuisance/odorous pollution episode of volatile organic compounds (VOCs) occur, a widely used active sampling methodology based on multi-sorbent bed tubes (Carbotrap, Carbopack X and Carboxen 569) and analysis through automatic thermal desorption-gas chromatography/mass spectrometry was used. Daily 24 h samples of multi-sorbent bed tubes were taken over a period of 14 days using an air collector pump sampler specially designed in the LCMA-UPC laboratory. Simultaneously, daily episodic samples were taken according to the activation of another LCMA-UPC sampler by the metal oxide semiconductor gas sensor. Sampling was done throughout January–February 2019 at El Morell (Tarragona, Spain), near the petrochemical area. All episode samples present higher concentrations of VOCs than 24 h samples, with an average ratio of 3.5 times for Total VOCs. VOC familial distributions present very similar values in 24 h and episode samples (r2 = 0.7466), correlating significatively (F-Snedecor, p < 0.05). A higher level of VOCs in the atmosphere in general, not derived from a specific compound or a VOC/s family/ies, seems to be the trigger of the activation of the sampler by the sensor. On the other hand, no significant correlations are observed between alcohols concentrations and relative humidity (F-Snedecor, p < 0.05). Additionally, Total VOCs concentrations in episode samples are in agreement with higher percentages of NE-SSE wind directions, coming from the petrochemical complex. Hence, these aspects validate the use of the evaluated sensor for its application for the activation of samplers in air quality evaluations when episodic events occur, an interesting and innovative technique. Thus, this study is an important contribution to the understanding of the performance of gas sensors and proposes an expansion of their field of use.

Additional details

Additional titles

Augmented title (English)
Volatile organic compounds;TD-GC/MS;Outdoor air quality;Gas sensor;Active sampling

Identifiers

DOI
10.1016/j.scitotenv.2019.133752;
PII
S0048969719336915;

Publishing Information

Journal Title
Science of the Total Environment
Journal Volume
694
Journal Page Range
vp.
ISSN
0048-9697
CODEN
STENDL

Optional Information

Copyright
Copyright (c) 2019 Elsevier B.V. All rights reserved.