Published February 1980
| Version v1
Journal article
Rapid repetitive scanning of impurity spectral line profiles in the vuv for Doppler temperature measurements in the TFR Tokamak
- 1. Association Euratom-CEA sur la Fusion, Centre d'Etudes Nucleaires de Fontenay-aux-Roses, 92 (France). Dept. de Physique du Plasma et de la Fusion Controlee
Description
A monochromator is described which is capable of high resolution (resolving power above 50 000) in the near vacuum ultraviolet spectral region. The instrument is equipped with a vibrating mirror before the exit slit, in order to scan the spectral line under study several times during one Tokamak discharge. Examples of ion temperature measurements in the plasma periphery by using impurity lines are given. (author)
Additional details
Publishing Information
- Journal Title
- J. Phys., E (London). Sci. Instrum.
- Journal Volume
- 13
- Journal Issue
- 2
- Series
- J. Phys., E (London). Sci. Instrum.
- Journal Page Range
- 216-226
- ISSN
- 0022-3735
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- United Kingdom
- INIS RN
- 11515264
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Descriptors DEI
- DATA ACQUISITION SYSTEMS; DOPPLER BROADENING; ENERGY RESOLUTION; EXTREME ULTRAVIOLET RADIATION; IMPURITIES; ION TEMPERATURE; LINE WIDTHS; MONOCHROMATORS; PLASMA DIAGNOSTICS; SPATIAL RESOLUTION; TFR TOKAMAK
- Descriptors DEC
- CLOSED PLASMA DEVICES; ELECTROMAGNETIC RADIATION; LINE BROADENING; RADIATIONS; RESOLUTION; THERMONUCLEAR DEVICES; TOKAMAK DEVICES; ULTRAVIOLET RADIATION