Published 1982
| Version v1
Miscellaneous
Power two-step dc circuit breaker
Description
A two-step circuit breaker with replaceable current-conducting elements is described. It is designed for a breakjng capacity of 6x109 W (the maximum current is 150 kA) with the 80-100 μs time of current transfer from inductive storage to the load and thermal stability of 1011 A2xs. A pneumatic circuit breaker with replaceable elements is used as the first step, and exploding-wire circuit breaker as the second one. The circuit breaker measures 1650x1360x1495 mm and weighs 1 t
Additional details
Additional titles
- Original title (Russian)
- Мощный двухступенчатый размыкател' постоянного тока
Publishing Information
- Imprint Title
- Reports on 2. All-union conference on technological problems of thermonuclear reactors. V. 3
- Journal Page Range
- p. 91-95.
- Report number
- INIS-SU--273
Conference
- Title
- 2. All-union conference on technological problems of thermonuclear reactors.
- Dates
- 23-25 Jun 1981.
- Place
- Leningrad (USSR).
INIS
- Country of Publication
- USSR
- Country of Input or Organization
- USSR
- INIS RN
- 16015929
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CIRCUIT BREAKERS; DIAGRAMS; DIRECT CURRENT; EXPLODING WIRES; SPECIFICATIONS
- Descriptors DEC
- CURRENTS; ELECTRIC CURRENTS; ELECTRICAL EQUIPMENT; EQUIPMENT; EQUIPMENT PROTECTION DEVICES; EXPLOSIONS; INFORMATION; WIRES
Optional Information
- Notes
- 2 figs. Imprint:Doklady vtoroj vsesoyuznoj konferentsii po inzhenernym problemam termoyadernykh reaktorov. Tom 3.