Published 1982 | Version v1
Miscellaneous

Power two-step dc circuit breaker

Description

A two-step circuit breaker with replaceable current-conducting elements is described. It is designed for a breakjng capacity of 6x109 W (the maximum current is 150 kA) with the 80-100 μs time of current transfer from inductive storage to the load and thermal stability of 1011 A2xs. A pneumatic circuit breaker with replaceable elements is used as the first step, and exploding-wire circuit breaker as the second one. The circuit breaker measures 1650x1360x1495 mm and weighs 1 t

Additional details

Additional titles

Original title (Russian)
Мощный двухступенчатый размыкател' постоянного тока

Publishing Information

Imprint Title
Reports on 2. All-union conference on technological problems of thermonuclear reactors. V. 3
Journal Page Range
p. 91-95.
Report number
INIS-SU--273

Conference

Title
2. All-union conference on technological problems of thermonuclear reactors.
Dates
23-25 Jun 1981.
Place
Leningrad (USSR).

INIS

Country of Publication
USSR
Country of Input or Organization
USSR
INIS RN
16015929
Subject category
S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CIRCUIT BREAKERS; DIAGRAMS; DIRECT CURRENT; EXPLODING WIRES; SPECIFICATIONS
Descriptors DEC
CURRENTS; ELECTRIC CURRENTS; ELECTRICAL EQUIPMENT; EQUIPMENT; EQUIPMENT PROTECTION DEVICES; EXPLOSIONS; INFORMATION; WIRES

Optional Information

Notes
2 figs. Imprint:Doklady vtoroj vsesoyuznoj konferentsii po inzhenernym problemam termoyadernykh reaktorov. Tom 3.