Desorption of 99Mo from spent 99Mo/99mTc generator

Creators

  • 1. Pakistan Inst. of Nuclear Science and Technology, Islamabad (Pakistan). Radioisotope Production Div.

Description

A simple method for desorption and purification of 99Mo from spent 99Mo/99mTc generators is described. The alumina column was washed successively with 0.9% saline water, 35% H2O2, and then the 99Mo was eluted with 2M NH4OH. Ammonia and residual H2O2 were removed by heating the eluate. Finally, 99Mo solution was passed through a 0.2 μm membrane filter to remove precipitated aluminium hydroxide. (author) 13 refs.; 1 tab

Additional details

Publishing Information

Journal Title
Journal of Radioanalytical and Nuclear Chemistry
Journal Volume
199
Journal Issue
2
Journal Page Range
p. 89-94.
ISSN
0236-5731
CODEN
JRNCDM