Published December 1991 | Version v1
Report Open

Spectrum-dose conversion operators, G(E) functions of NaI(Tl) scintillators adapted for effective dose equivalent quantities

  • 1. Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

Description

G(E) functions of spectrum-dose conversion operators are shown for eight kinds of NaI(Tl) scintillators for various radiation quantities. The G(E) function method evaluates dose directly from an observed gamma-ray pulse-height spectrum with ease and high accuracy. Dimensions of the considered detectors are 1''φ x 1'', 2''φ x 2'', 3''φ x 3'', 4''φ x 4'', 5''φ x 4'' for cylindrical type and 2''φ, 3''φ, 5''φ for spherical type. For radiation quantities, four kinds of kermas, four kinds of 1 cm depth dose equivalents in the ICRU sphere, and effective dose equivalents calculated with a numerical human phantom under five irradiation geometries are considered. The energy range of gamma-rays is 50 keV to 10 MeV. The detector response functions calculated by a Monte Carlo simulation code, MARTHA were used to derive G(E) functions. (author)

Availability note (English)

MF available from INIS under the Report Number.

Files

23032206.pdf

Files (9.7 MB)

Name Size Download all
md5:6f683fae551244eb410ad5fbdcc6ddbe
9.7 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
158 p.
Report number