MR imaging of lymph nodes using gadofluorine M. Feasibility in a swine model at 1.5 amd 3T

  • 1. Universitaetsklinikum Koeln (Germany). Inst. und Poliklinik fuer Radiologie
  • 2. Universitaetsklinikum RWTH Aachen (Germany). Klinik fuer Radiologische Diagnostik
  • 3. Klinikum Saarbruecken (Germany), Inst. fuer Radiologie
  • 4. Bayer-Schering Pharma AG, Berlin (Germany)
  • 5. King's College London (United Kingdom). Imaging Sciences Division
  • 6. Saarland Univ. (Germany). Diagnostische und Interventionelle Radiologie

Description

Purpose: To investigate the potential of Gadofluorine M for targeted lymph node imaging in a human size animal model and on a clinical MR scanner at 1.5 and 3 T. Materials and Methods: Pelvic and cervical lymph nodes in a swine model were investigated prior to and 24 hours after intravenous administration of 50 μmol/kg body weight Gadofluorine M, an experimental contrast agent. MR imaging was carried out on clinical 1.5 T and 3 T whole-body MR systems using clinically available coils and T 1-weighted sequences. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) with respect to the surrounding tissue were assessed and compared using the Student's t-test. The Gd concentration in the lymph nodes (n = 43) was measured post mortem by Inductively Coupled Plasma-Atomic Emission Spectroscopy (ICP-AES). Results: Gadofluorine M allowed for high signal and high contrast visualization of lymph nodes in all stations on post-contrast images with a significantly increased SNR and CNR (SNR pelvic lymph nodes post vs. pre: 46 ± 7 vs. 14 ± 3, SNR cervical lymph nodes post vs. pre: 105 ± 64 vs. 32 ± 21; CNR pelvic lymph node vs. muscle post vs. pre 28 ± 5 vs. 0.2 ± 0.5, CNR cervical lymph node vs. muscle post vs. pre 76 ± 53 vs. 11 ± 15, p < 0.05 for all comparisons). The SNR and CNR in the pelvis were further improved using 3 T compared to 1.5 T scanners (SNR lymph nodes 3 T vs. 1.5 T 84 ± 6 vs. 46 ± 7, CNR lymph node vs. muscle 3 T vs. 1.5 T 53 ± 9 vs. 28 ± 5 respectively, p < 0.05). A high concentration of Gd in the lymph nodes was found (149 ± 25 mmol Gd/L). Conclusion: Gadofluorine M accumulates in the lymph nodes and allows for selective targeted high contrast MR imaging of lymph node tissue in a large animal model using clinically available MR imaging techniques. 3 T further improves SNR and CNR compared to 1.5 T. (orig.)

Additional details

Publishing Information

Journal Title
RoeFo - Fortschritte auf dem Gebiete der Roentgenstrahlen und der bildgebenden Verfahren
Journal Volume
182
Journal Issue
8
Journal Page Range
p. 698-705
ISSN
1438-9029
CODEN
RFGNDO

INIS

Country of Publication
Germany
Country of Input or Organization
Germany
INIS RN
41105779
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
BIOLOGICAL MODELS; FEASIBILITY STUDIES; LYMPH NODES; NMR IMAGING; SWINE
Descriptors DEC
ANIMALS; DIAGNOSTIC TECHNIQUES; DOMESTIC ANIMALS; LYMPHATIC SYSTEM; MAMMALS; VERTEBRATES