Project management of the San Onofre steam generator chemical cleaning
Creators
- 1. Southern California Edison Co., San Clemente, CA (United States)
Description
The San Onofre Nuclear Generating Station (SONGS) units 2 and 3 is a 3410-MW(thermal) dual-unit Combustion Engineering (CE) pressurized water reactor (PWR). Each of the units' four reactor coolant loops utilizes two vertical U-tube recirculating steam generators (SGs) to transfer heat to a secondary steam plant. The SONGS Steam Generator Strategic Plan was developed to optimize the operation, maintenance, and working life of the SGs. The plan called for SG chemical cleaning (SGCC) during the units' respective cycle-10 refueling outages. Free-span SG tube cracking at other CE PWRs in 1995 and 1996, resulted in the decision to accelerate the SGCC to the cycle-9 refueling outages
Additional details
Publishing Information
- Journal Title
- Transactions of the American Nuclear Society
- Journal Volume
- 77
- Journal Page Range
- p. 296.
- ISSN
- 0003-018X
- CODEN
- TANSAO
Conference
- Title
- 1997 American Nuclear Society (ANS) winter meeting.
- Dates
- 16-20 Nov 1997.
- Place
- Albuquerque, NM (United States).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 29021060
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CLEANING; DEPOSITS; MAINTENANCE; MANAGEMENT; OUTAGES; SAN ONOFRE-2 REACTOR; SAN ONOFRE-3 REACTOR; STEAM; STEAM GENERATORS; TUBES
- Descriptors DEC
- BOILERS; ENRICHED URANIUM REACTORS; POWER REACTORS; PWR TYPE REACTORS; REACTORS; THERMAL REACTORS; VAPOR GENERATORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Secondary number(s)
- CONF-971125--.