Pulmonary subsolid nodules. Value of semi-automatic measurement in diagnostic accuracy, diagnostic reproducibility and nodule classification agreement
Creators
- 1. Seoul National University Medical Research Center, Institute of Radiation Medicine, Seoul (Korea, Republic of)
- 2. Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of)
- 3. Seoul National University Cancer Research Institute, Seoul (Korea, Republic of)
Description
We hypothesized that semi-automatic diameter measurements would improve the accuracy and reproducibility in discriminating preinvasive lesions and minimally invasive adenocarcinomas from invasive pulmonary adenocarcinomas appearing as subsolid nodules (SSNs) and increase the reproducibility in classifying SSNs. Two readers independently performed semi-automatic and manual measurements of the diameters of 102 SSNs and their solid portions. Diagnostic performance in predicting invasive adenocarcinoma based on diameters was tested using logistic regression analysis with subsequent receiver operating characteristic curves. Inter- and intrareader reproducibilities of diagnosis and SSN classification according to Fleischner's guidelines were investigated for each measurement method using Cohen's κ statistics. Semi-automatic effective diameter measurements were superior to manual average diameters for the diagnosis of invasive adenocarcinoma (AUC, 0.905-0.923 for semi-automatic measurement and 0.833-0.864 for manual measurement; p<0.05). Reproducibility of diagnosis between the readers also improved with semi-automatic measurement (κ=0.924 for semi-automatic measurement and 0.690 for manual measurement, p=0.012). Inter-reader SSN classification reproducibility was significantly higher with semi-automatic measurement (κ=0.861 for semi-automatic measurement and 0.683 for manual measurement, p=0.022). Semi-automatic effective diameter measurement offers an opportunity to improve diagnostic accuracy and reproducibility as well as the classification reproducibility of SSNs. (orig.)
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00330-017-5171-7Additional details
Identifiers
Publishing Information
- Journal Title
- European Radiology
- Journal Volume
- 28
- Journal Issue
- 5
- Journal Page Range
- p. 2124-2133
- ISSN
- 0938-7994
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 49054301
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ACCURACY; AUTOMATION; CARCINOMAS; CLASSIFICATION; COMPUTERIZED TOMOGRAPHY; DIAGNOSIS; HISTOLOGY; LUNGS; MEASURING METHODS; MILLI GY RANGE 01-10; PATHOLOGICAL CHANGES; RADIATION DOSES; SIZE
- Descriptors DEC
- ABSORBED DOSE RANGE; BODY; DIAGNOSTIC TECHNIQUES; DISEASES; DOSES; MILLI GY RANGE; NEOPLASMS; ORGANS; RADIATION DOSE RANGES; RESPIRATORY SYSTEM; TOMOGRAPHY