6. Experimental assessment of seismic resistance of technological equipment
Creators
Description
Procedures are described used for testing seismic resistance as are types of tests and methods of simulating seismic excitation. The seismic resistance of electric equipment is tested on a vibrostand or a vibration table with hydraulic cylinders simulating seismic excitation inputted using accelerograms or response spectra at points of anchorino.. Testing is performed within the frequency range of 0.5 to 50 Hz. Testing and operating anchorage must be identical. Seismic resistance of the electric equipment of the Mochovce nuclear power plant will have to be determined by computation and tests of small electrical devices - this is because large seismic stands are not available in Czechoslovakia. (E.F.)
Additional details
Additional titles
- Original title (Czech)
- 6. Experimentalni hodnoceni seizmicke odolnosti technologickeho zarizeni
Publishing Information
- Imprint Title
- Seismic effects on technological equipment and systems of nuclear power plants
- Imprint Pagination
- 84 p.
- Journal Page Range
- p. 59-65.
- Report number
- INIS-mf--9711
INIS
- Country of Publication
- Serbia and Montenegro
- Country of Input or Organization
- Serbia and Montenegro
- INIS RN
- 16045369
- Subject category
- S58: GEOSCIENCES;
- Descriptors DEI
- ELECTRICAL EQUIPMENT; FREQUENCY RESPONSE TESTING; HZ RANGE; MECHANICAL VIBRATIONS; NUCLEAR POWER PLANTS; SEISMIC EFFECTS
- Descriptors DEC
- EQUIPMENT; FREQUENCY RANGE; NUCLEAR FACILITIES; POWER PLANTS; TESTING; THERMAL POWER PLANTS
Optional Information
- Notes
- Imprint:Vlivy zemetreseni na technologicke zarizeni a systemy jadernych elektraren.