Published April 21, 2010 | Version v1
Journal article

A HTS scanning magnet and AC operation

  • 1. Research Center for Nuclear Physics, Osaka University, Ibaraki, Osaka 567-0047 (Japan)
  • 2. Cyclotron and Radioisotope Center, Tohoku University, Sendai, Miyagi 980-8578 (Japan)
  • 3. KT Science Ltd., Fujie, Akasi, Hyogo 673-0044 (Japan)
  • 4. National Institute of Radiological Sciences, Chiba 263-8555 (Japan)

Description

A scanning magnet using high-temperature superconductor (HTS) wire was designed, built, and tested for its suitability as a beam scanner. After successful cooling tests, the magnet performance was studied using DC and AC currents. With DC current the magnet was successfully operated to generate designed field distributions and effective length. In AC mode, the magnet was operated at frequencies of 30-59 Hz and a temperature of 77 K as well as 10-20 Hz and 20 K. The power losses dissipated in the coils were measured and compared with the model calculations. The observed losses per cycle were independent of the frequency and the scaling law of the transport current was consistent with theoretical predictions for hysteretic losses in HTS wires.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.nima.2010.02.068

Additional details

Identifiers

DOI
10.1016/j.nima.2010.02.068;
PII
S0168-9002(10)00266-4;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
616
Journal Issue
1
Journal Page Range
p. 16-20
ISSN
0168-9002
CODEN
NIMAER

Optional Information

Copyright
Copyright (c) 2010 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.