Published July 2016 | Version v1
Journal article

Basic study on BWR plant behavior under the condition of severe accident (2)

  • 1. Fukui University of Technology, Department of Applied Nuclear Technology, Fukui (Japan)

Description

In this paper, we report on the results using the BWR plant simulator about the plant behavior under the condition of the two types of severe accidents that LOCA occurs but ECCS fails the water irrigation into the reactor core and SBO occurs and at the same time the reclosed failure of SRV occurs. The simulation experiments were carried out for the cases that LOCA has occurred in the main feed-water piping. As for the results about the relationship between the LOCA area and the time from LOCA occurs until the fuel temperature rise start, the effect that RCIC operated was extremely big for small and middle LOCA area. In the case of main feed-water system LOCA, the core water level suddenly decreased for large LOCA of 2000 cm2 area, however, if the irrigation into the reactor core was carried out 30 min after LOCA occurrence, the core had little damage. In addition, the H2 concentration in the containment vessel did not exceed both limits of H2 explosion nor detonation. The pressure of the containment vessel was around 3 kg/cm2 of design value, so the soundness of the containment vessel was confirmed. On the other hand, for the accident of SBO with reclosed failure of SRV, it has been shown that the accidents continue to progress rapidly as compared with the case of normally operating of SRV. Because SRV has the function that keep the inside pressure of reactor core by repeating opened and closed in response of the inside pressure and prevent the decrease of water level inside reactor core. However, if the irrigation into the reactor core was carried out 30 min after SBO occurrence, the core had little damage and also the H2 concentration in the containment vessel did not exceed limits of H2 explosion. Further, as for the accident of reclosed failure of SRV, it has been shown that there are very good correspondence with the simulation results of main steam piping LOCA of area 180 cm2 corresponding to the inlet cross-sectional area SRV installed on the piping. Therefore, the accident of reclosed failure has been also shown that can be regarded as small LOCA accidents of main steam piping. (author)

Availability note (English)

Available from DOI: http://doi.org/10.57375/00001585

Additional details

Additional titles

Original title (Japanese)
シビアアクシデント発生時におけるBWR プラント挙動の基礎的研究 (2).(給水系LOCA+ECCS 注入失敗)事故と(SBO+SRV 開固着)事故

Identifiers

Publishing Information

Journal Title
Fukui Kogyo Daigaku Kenkyu Kiyo (Online)
Journal Volume
46
Journal Page Range
p. 148-159
ISSN
1884-4456

Optional Information

Notes
10 refs., 23 figs., 1 tab.; This record replaces 48092539