Published January 1976 | Version v1
Journal article

Operating experience with the DORIS electron-positron-double storage ring

Creators

  • 1. Deutsches Elektronen-Synchrotron (DESY), Hamburg (F.R. Germany)

Description

The DORIS double storage ring has supplied physics experiment with luminosity which is now available for 90% of the operating time since the autumn of 1974. Luminosities averaging above 4 x 1029 cm-2 s-1 are reached at energies between 1.5 and 2 GeV, peak values are about 1030 cm-2 s-1. The life of the beam exceeds 10 h. Detailed studies of the beam properties, such as optical resonances and instabilities caused by cavities, and technical measures for their reduction were required to reach these values. (orig.)

Abstract (German)

Seit Herbst 1974 versorgt der Doppelspeicherring DORIS physikalische Experimente mit Luminositaet, die inzwischen waehrend 90% der Betriebszeit zur Verfuegung steht. Im Mittel werden bei Energien zwischen 1,5 und 2 GeV Luminositaeten ueber 4 x 1029 cm-2 s-1 erreicht, Spitzenwerte liegen um 1030 cm-2 s-1. Die Strahllebensdauer betraegt mehr als 10 Stunden. Um diese Werte zu erreichen, waren eingehende Studien der Strahleigenschaften, wie optische Resonanzen und durch die Beschleunigungsstrecken hervorgerufene Instabilititaeten, und technische Massnahmen zu deren Bekaempfung erforderlich. (orig.)

Additional details

Additional titles

Original title (German)
Betriebserfahrung mit dem Elektron-Positron-Doppelspeicherring DORIS

Publishing Information

Journal Title
Kerntechnik
Journal Volume
18
Journal Issue
1
Series
Kerntechnik.
Journal Page Range
9-14

INIS

Country of Publication
Germany
Country of Input or Organization
Germany
INIS RN
7256022
Subject category
S43: PARTICLE ACCELERATORS;
Descriptors DEI
ACCELERATOR FACILITIES; BEAM CURRENTS; BEAM DYNAMICS; BEAM LUMINOSITY; BEAM PROFILES; DORIS STORAGE RING
Descriptors DEC
CURRENTS; STORAGE RINGS

Optional Information

Notes
7 figs.; 5 refs.