Published April 2010 | Version v1
Journal article

Evaluation of Magnetic Resonance Imaging-Compatible Needles and Interactive Sequences for Musculoskeletal Interventions Using an Open High-Field Magnetic Resonance Imaging Scanner

  • 1. University Medicine Berlin, Department of Radiology, Charite (Germany)
  • 2. Philips Medical Systems (Germany)

Description

In this article, we study in vitro evaluation of needle artefacts and image quality for musculoskeletal laser-interventions in an open high-field magnetic resonance imaging (MRI) scanner at 1.0T with vertical field orientation. Five commercially available MRI-compatible puncture needles were assessed based on artefact characteristics in a CuSO4 phantom (0.1%) and in human cadaveric lumbar spines. First, six different interventional sequences were evaluated with varying needle orientation to the main magnetic field B0 (0o to 90o) in a sequence test. Artefact width, needle-tip error, and contrast-to-noise ratio (CNR) were calculated. Second, a gradient-echo sequence used for thermometric monitoring was assessed and in varying echo times, artefact width, tip error, and signal-to-noise ratio (SNR) were measured. Artefact width and needle-tip error correlated with needle material, instrument orientation to B0, and sequence type. Fast spin-echo sequences produced the smallest needle artefacts for all needles, except for the carbon fibre needle (width <3.5 mm, tip error <2 mm) at 45o to B0. Overall, the proton density-weighted spin-echo sequences had the best CNR (CNRMuscle/Needle >16.8). Concerning the thermometric gradient echo sequence, artefacts remained <5 mm, and the SNR reached its maximum at an echo time of 15 ms. If needle materials and sequences are accordingly combined, guidance and monitoring of musculoskeletal laser interventions may be feasible in a vertical magnetic field at 1.0T.

Additional details

Identifiers

Publishing Information

Journal Title
Cardiovascular and Interventional Radiology
Journal Volume
33
Journal Issue
2
Journal Page Range
p. 346-351
ISSN
0174-1551
CODEN
CAIRDG

Conference

Title
Congress of th Cardiovascular and Interventional Radiological Society of Europe
Acronym
CIRSE 2010
Dates
2-6 Oct 2010
Place
Valencia (Spain)

INIS

Country of Publication
United States
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
42029087
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Resource subtype / Literary indicator
Conference
Descriptors DEI
EVALUATION; IMAGE SCANNERS; NMR IMAGING; VERTEBRAE
Descriptors DEC
BODY; DIAGNOSTIC TECHNIQUES; ORGANS; SKELETON

Optional Information

Copyright
Copyright (c) 2010 Springer Science+Business Media, LLC and the Cardiovascular and Interventional Radiological Society of Europe (CIRSE)