Published May 19, 1992
| Version v1
Miscellaneous
OTIS/220402, Once-Through Integral Systems, Cold Leg Small Break LOCA
Description
1 - Description of test facility: OTIS is a 1:1686 volume-scaled single loop (one hot log and one cold leg) facility with critical elevations preserved. The single once-through steam generator contains 19 tubes prototypical of a B and W PWR plant. The electrically heated core has a power capability of 180 KW which is representative of 10 per cent scaled power based on a 2584 MWth plant. It contains no primary pump but all other active components are simulated and it operates at full PWR system pressure. 2 - Description of test: Cold leg small break LOCA
Availability note (English)
Available on-line: http://www.nea.fr/abs/html/csni0015.htmlAdditional details
Identifiers
Publishing Information
- Imprint Pagination
- [html]
INIS
- Country of Publication
- Nuclear Energy Agency of the OECD (NEA)
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 40013843
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Resource subtype / Literary indicator
- Non-conventional Literature
- Descriptors DEI
- COMPUTERIZED SIMULATION; LOSS OF COOLANT; PWR TYPE REACTORS; REACTOR ACCIDENT SIMULATION; STEAM GENERATORS; TEST FACILITIES; TRANSIENTS; WEBSITES
- Descriptors DEC
- ACCIDENTS; BOILERS; DOCUMENT TYPES; ENRICHED URANIUM REACTORS; POWER REACTORS; REACTOR ACCIDENTS; REACTORS; SIMULATION; THERMAL REACTORS; VAPOR GENERATORS; WATER COOLED REACTORS; WATER MODERATED REACTORS
Optional Information
- Notes
- refs.