Published May 19, 1992 | Version v1
Miscellaneous

OTIS/220402, Once-Through Integral Systems, Cold Leg Small Break LOCA

Description

1 - Description of test facility: OTIS is a 1:1686 volume-scaled single loop (one hot log and one cold leg) facility with critical elevations preserved. The single once-through steam generator contains 19 tubes prototypical of a B and W PWR plant. The electrically heated core has a power capability of 180 KW which is representative of 10 per cent scaled power based on a 2584 MWth plant. It contains no primary pump but all other active components are simulated and it operates at full PWR system pressure. 2 - Description of test: Cold leg small break LOCA

Availability note (English)

Available on-line: http://www.nea.fr/abs/html/csni0015.html

Additional details

Publishing Information

Imprint Pagination
[html]

INIS

Country of Publication
Nuclear Energy Agency of the OECD (NEA)
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
40013843
Subject category
S22: GENERAL STUDIES OF NUCLEAR REACTORS;
Resource subtype / Literary indicator
Non-conventional Literature
Descriptors DEI
COMPUTERIZED SIMULATION; LOSS OF COOLANT; PWR TYPE REACTORS; REACTOR ACCIDENT SIMULATION; STEAM GENERATORS; TEST FACILITIES; TRANSIENTS; WEBSITES
Descriptors DEC
ACCIDENTS; BOILERS; DOCUMENT TYPES; ENRICHED URANIUM REACTORS; POWER REACTORS; REACTOR ACCIDENTS; REACTORS; SIMULATION; THERMAL REACTORS; VAPOR GENERATORS; WATER COOLED REACTORS; WATER MODERATED REACTORS

Optional Information

Notes
refs.