Measurements and calculations of absorbed dose in electron beam radiation processing

  • 1. Sichuan Univ., Chengdu, SC (China). Inst. of Nuclear Science and Technology

Description

An electron beam current densimeter has been described and used for dose measurement in EB radiation processing. An improved bipartition model of electron transport is applied to calculate the reflection coefficients and energy deposition distributions produced by 0.2 - 3 MeV electrons in semi-infinite media of Al, C, and nylon, and the energy deposition produced by 2 MeV electrons in the two - layer medium consisting of copper and polystyrene. In addition, the depth dose distribution of 300 keV electrons in Ti-air-nylon composite -layer has been evaluated. The calculation results are in good agreement with the measurement data. (Author)

Additional details

Publishing Information

Journal Title
Radiation Physics and Chemistry
Journal Volume
42
Journal Issue
4-6
Journal Page Range
p. 817-820.
ISSN
0146-5724
CODEN
RPCHDM

Conference

Title
8. international meeting on radiation processing.
Dates
13-18 Sep 1992.
Place
Beijing (China).