Published August 9, 2000
| Version v1
Report
Restricted
Availability Analysis of the Ventilation Stack CAM Interlock System
Description
Ventilation Stack Continuous Air Monitor (CAM) Interlock System failure modes, failure frequencies, and system availability have been evaluated for the RPP. The evaluation concludes that CAM availability is as high as assumed in the safety analysis and that the current routine system surveillance is adequate to maintain this availability credited in the safety analysis, nor is such an arrangement predicted to significantly improve system availability
Availability note (English)
Available from INIS in electronic form; Also available from OSTI as DE00804478; PURL: https://www.osti.gov/servlets/purl/804478-Dl6q2O/webviewable/
Files
Additional details
Identifiers
Publishing Information
- Imprint Pagination
- 45 p.
- Report number
- RPP--5453/Rev.1
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 34022494
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S11: NUCLEAR FUEL CYCLE AND FUEL MATERIALS; S12: MANAGEMENT OF RADIOACTIVE WASTES, AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES;
- Descriptors DEI
- AIR POLLUTION MONITORS; AVAILABILITY; INTERLOCKS; RADIATION MONITORING; RADIATION PROTECTION; SAFETY ANALYSIS; STACKS; VENTILATION SYSTEMS
- Descriptors DEC
- MEASURING INSTRUMENTS; MONITORING; MONITORS
Optional Information
- Contract/Grant/Project number
- ECN-661800; AC27-99RL14047
- Funding organization
- USDOE Office of Environmental Management (EM) (United States)