Published November 2014 | Version v1
Journal article

Assessment of scaling distortion in condensation film heat transfer

  • 1. Institute of Nuclear and New Energy Technology, Tsinghua University, Beijing (China)
  • 2. Beijing R and D Center of State Nuclear Power Technology Corporation, Beijing (China)

Description

The scale-down separate and integral test facilities are of vital significance for the research and development of both large-scale advanced pressurized water reactor nuclear power plants and the related analytical codes. However, the distortions of some phenomena induced by the reduced size have directly affected both the design of the facility and the understanding of the test results. Through the equivalent heat transfer coefficient, the distortion of condensation film heat transfer on the inner side of PCS was assessed. With the use of H2TS scaling method, the effect of this distortion on the modeling of containment pressure change response was analyzed. The results show that the scale-down of a test facility has a conservative influence on the condensation film heat transfer. (authors)

Additional details

Identifiers

Publishing Information

Journal Title
Atomic Energy Science and Technology
Journal Volume
48
Journal Issue
11
Journal Page Range
p. 1969-1975
ISSN
1000-6931

Optional Information

Notes
5 figs., 3 tabs., 14 refs.; http://dx.doi.org/10.7538/yzk.2014.48.11.1969