Novel x-ray attenuation mechanism: Role of interatomic distance
- 1. Nora Eccles Harrison Cardiovascular Research and Training Institute and Bioengineering, University of Utah, 95 South 2000 East, Salt Lake City, Utah 84112 (United States)
Description
Little progress has been made over the last 30 years for improving attenuation by x-ray contrast agents, in part because the mechanisms of x-ray attenuation are thought to be well understood. We hypothesized that x-ray absorbance can be modulated by altering the interatomic spacing between K-edge attenuating atoms. Iodomethane, diiodomethane, 2,6-diiodo-4-nitroanaline, and diiodobenzene isomers were dissolved in DMSO and imaged with an OEC Compact 7600 fluoroscope. At a tube voltage of 42 kVp, absorbance of equimolar diiodomethane (150 mM) was significantly (p<0.01) greater than iodomethane (150 mM) by 45%. Interestingly, 150 mM diiodomethane absorbance was significantly greater than 300 mM iodomethane (by 5%, p<0.01) despite equal amounts of iodine in both solutions. 1,3-diiodobenzene absorbance was significantly greater than 1,2- and 1,4-diiodobenzene (p<0.01). However, 2,6-diiodo-4-nitroanaline absorbance was similar to 1,3-diiodobenzene. When a linear model was fit for absorbance as a function of density and harmonic error (the fractional remainder of the inter-iodine distance and the K-shell ionizing wavelength) at different beam energies, a significant overall fit was obtained for both unfiltered and hardened beams (p<0.01). While the slope of absorbance as a function of harmonic error was significant for all conditions (p<0.01), the slope with respect to density was significant only when the beam was unfiltered (p<0.05). Also harmonic error, but not density, displayed significant energy-dependent effects on absorbance (p<0.01). These data suggest that harmonic error is a strong determinant of absorbance, particularly when the beam energy is concentrated near the iodine K-edge and is likely a descriptor of K-characteristic photon interactions. Therefore, x-ray absorbance may be modulated by the distance between covalently linked x-ray K-edge attenuating atoms. This finding has important implications for increasing contrast agent absorbance as well as for designing molecular transducers capable of modulating K-edge attenuating atomic distances and thereby x-ray absorbance.
Additional details
Identifiers
- DOI
- 10.1118/1.2975151;
Publishing Information
- Journal Title
- Medical Physics
- Journal Volume
- 35
- Journal Issue
- 10
- Journal Page Range
- p. 4386-4395
- ISSN
- 0094-2405
- CODEN
- MPHYA6
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 44058535
- Subject category
- S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY; S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ABSORPTION; ATTENUATION; ENERGY DEPENDENCE; ERRORS; INTERACTIONS; INTERATOMIC DISTANCES; IODINE; K SHELL; PHOTON BEAMS; SOLUTIONS; X RADIATION
- Descriptors DEC
- BEAMS; DISPERSIONS; DISTANCE; ELECTROMAGNETIC RADIATION; ELECTRONIC STRUCTURE; ELEMENTS; HALOGENS; HOMOGENEOUS MIXTURES; IONIZING RADIATIONS; MIXTURES; NONMETALS; RADIATIONS; SORPTION
Optional Information
- Notes
- (c) 2008 American Association of Physicists in Medicine