Dewatering Treatment Scale-up Testing Results of Hanford Tank Wastes

  • 1. CH2M HILL Hanford Group, Inc. Richland, WA (United States)

Description

This report documents CH2M HILL Hanford Group Inc. (CH2M HILL) 2007 dryer testing results in Richland, WA at the AMEC Nuclear Ltd., GeoMelt Division (AMEC) Horn Rapids Test Site. It provides a discussion of scope and results to qualify the dryer system as a viable unit-operation in the continuing evaluation of the bulk vitrification process. A 10,000 liter (L) dryer/mixer was tested for supplemental treatment of Hanford tank low activity wastes, drying and mixing a simulated non-radioactive salt solution with glass forming minerals. Testing validated the full scale equipment for producing dried product similar to smaller scale tests, and qualified the dryer system for a subsequent integrated dryer/vitrification test using the same simulant and glass formers. The dryer system is planned for installation at the Hanford tank farms to dry/mix radioactive waste for final treatment evaluation of the supplemental bulk vitrification process. (authors)

Availability note (English)

Available from: WM Symposia, 1628 E. Southern Avenue, Suite 9 - 332, Tempe, AZ 85282 (US); also available online at: http://www.wmsym.org/archives/2008/search.html

Additional details

Publishing Information

Imprint Pagination
15 p.
Report number
INIS-US--10-WM-08259

Conference

Title
HLW, TRU, LLW/ILW, Mixed, Hazardous Wastes and Environmental Management - Phoenix Rising: Moving Forward in Waste Management
Acronym
2008 Waste Management Symposium - WM2008/WM'08
Dates
24-28 Feb 2008
Place
Phoenix, AZ (United States)

Optional Information

Notes
5 refs.