Published October 2011
| Version v1
Miscellaneous
Effect of the Number of Detectors on Image Quality in Industrial SPECT
- 1. Hanyang University, Seoul (Korea, Republic of)
- 2. Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)
Description
In industrial process plants, radioisotopes have been widely used to examine the spatial distribution, mixing characteristics, and flow pattern of process media. However, it is still a great challenge to acquire a reliable result for imaging a multiphase flow in a refinery and petrochemical plant on a real-time. Legoupil et al. proposed an industrial single photon emission computed tomography (SPECT) to image the flow distributions of a process system. The SPECT system has the advantage of a real-time estimation and analysis of flow distribution. In this study, to evaluate the effect of the number of detectors on image quality in industrial SPECT, several different geometries were simulated by the Monte Carlo method
Additional details
Publishing Information
- Publisher
- KNS
- Imprint Place
- Daejeon (Korea, Republic of)
- Imprint Title
- Proceedings of the KNS autumn meeting
- Imprint Pagination
- [1 CD-ROM]
- Journal Page Range
- [2 p.]
Conference
- Title
- 2011 autumn meeting of the KNS
- Dates
- 26-28 Oct 2011
- Place
- Kyoungju (Korea, Republic of)
INIS
- Country of Publication
- Korea, Republic of
- Country of Input or Organization
- Korea, Republic of
- INIS RN
- 43045605
- Subject category
- S07: ISOTOPES AND RADIATION SOURCES;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- IMAGES; MONTE CARLO METHOD; MULTIPHASE FLOW; RADIOISOTOPES; SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY; SPATIAL DISTRIBUTION
- Descriptors DEC
- CALCULATION METHODS; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; DISTRIBUTION; EMISSION COMPUTED TOMOGRAPHY; FLUID FLOW; ISOTOPES; TOMOGRAPHY
Optional Information
- Notes
- 6 refs, 4 figs