Published July 1992 | Version v1
Report Open

A gamma/neutron-discriminating, Cooled, Optically Stimulated Luminescence (COSL) dosemeter

Description

The Cooled Optically Stimulated Luminescence (COSL) of CaF2:Mn (grain sizes from 0.1 to 100 microns) powder embedded in a hydrogenous matrix is reported as a function of fast-neutron dose. When all the CaF2:Mn grains are interrogated at once, the COSL plastic dosemeters have a minimum detectable limit of 1 cSv fast neutrons; the gamma component from the bare 252cf exposure was determined with a separate dosemeter. We report here on a proton-recoil-based dosemeter that generates pulse height spectra, much like the scintillator of Hornyak, (2) to provide information on both the neutron and gamma dose

Availability note (English)

MF available from INIS under the Report Number; OSTI as DE92019429; NTIS; INIS; US Govt. Printing Office Dep.

Files

24011892.pdf

Files (1.3 MB)

Name Size Download all
md5:251d265d5f1675e3a7e72c6b69d08231
1.3 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
18 p.
Report number
PNL-SA--20304

Conference

Title
10. international conference on solid state dosimetry.
Dates
13-17 Jul 1992.
Place
Washington, DC (United States).

Optional Information

Contract/Grant/Project number
Contract AC06-76RL01830
Funding organization
USDOE, Washington, DC (United States).
Secondary number(s)
CONF-920702--3.