Absorbed dose and image quality in examinations of the colon with digital and analogue techniques
Creators
- 1. Dept. of Radiation Physics, Faculty of Health Sciences, Univ. Hospital, Linkoeping (Sweden)
- 2. Dept. of Diagnostic Radiology, Faculty of Health Sciences, Univ. Hospital, Linkoeping (Sweden)
Description
Purpose: Image quality and the absorbed dose to the patient are issues of primary interest in the change-over from the conventional analogue technique to the digital technique in the examination of the colon by means of fluoroscopy. The aim of this study was to compare the incident radiation and to evaluate the image quality in two different X-ray equipment types, one digital and one analogue. Material and Methods: A kerma-area product meter was used to measure the incident radiation to the patient. Both fluoroscopy and total-examination times were measured as was the number of images. An evaluation of image quality was made and statistically analysed. Results and Conclusion: No significant difference in the irradiation dose was observed between the two techniques. The fluoroscopy time was significantly lower with the conventional technique but the total-examination time decreased by 18% with the digital technique. The total number of images taken was higher with the digital technique (25 images compared to 19) owing to the limited field of the image intensifier. Significantly more noise and less sharpness were observed with the digital system but there was no significant difference in contrast or image quality in the various anatomical structures. Although the change-over to the digital system produced a reduction in sharpness and an increase in noise, and no significant dose saving was measured, the digital system was faster to work with and could well be used for diagnostic purposes. (orig.)
Additional details
Publishing Information
- Journal Title
- Acta Radiologica
- Journal Volume
- 38
- Journal Issue
- 6
- Journal Page Range
- p. 1010-1014.
- ISSN
- 0284-1851
- CODEN
- ACRAE3
INIS
- Country of Publication
- Sweden
- Country of Input or Organization
- Sweden
- INIS RN
- 29012181
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY; S62: RADIOLOGY AND NUCLEAR MEDICINE; S07: ISOTOPES AND RADIATION SOURCES;
- Descriptors DEI
- BIOMEDICAL RADIOGRAPHY; DOSIMETRY; IMAGES; KERMA; LARGE INTESTINE; PATIENTS; QUALITY ASSURANCE; RADIATION DOSES; X-RAY RADIOGRAPHY
- Descriptors DEC
- ANIMALS; BODY; DIAGNOSTIC TECHNIQUES; DIGESTIVE SYSTEM; GASTROINTESTINAL TRACT; INTESTINES; MAMMALS; MAN; MEDICINE; ORGANS; PRIMATES; VERTEBRATES