Evaluation of image quality using 1 : 1 pitch and 1.5 : 1 pitch helical CT in children: a comparative study
Creators
- 1. Department of Radiology, Loyola University Medical Center, Maywood, IL (United States)
- 2. Department of Mathematical Sciences, Oakland University, Rochester, MI (United States)
Description
Objective. The objective of this study was to compare the quality of 1 : 1 and 1.5 : 1 pitch helical contrast-enhanced thoracic and abdominal CT images in children who cannot cooperate for breath holding. Materials and methods. This is a retrospective study of 33 contrast-enhanced CT examinations in 11 children of 0-4 years of age. All children had an initial CT study using 1 : 1 pitch helical scanning followed over the next 6-36 months by one to four CT examinations with 1.5 : 1 pitch. Radiation dose with the two techniques was measured with a pencil ionization chamber. Results. The two techniques provided comparable overall image quality. There was 33 % less radiation dose with 1.5 : 1 pitch helical scanning. Conclusion. The 1.5 : 1 pitch helical CT provides comparable quality images and a smaller radiation dose than 1 : 1 pitch in examining children aged 0-4 years. (orig.). With 1 tab
Additional details
Publishing Information
- Journal Title
- Pediatric Radiology
- Journal Volume
- 26
- Journal Issue
- 12
- Journal Page Range
- p. 891-893.
- ISSN
- 0301-0449
- CODEN
- PDRYA5
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 28018074
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ABDOMEN; CHEST; COMPUTERIZED TOMOGRAPHY; CONTRAST MEDIA; DIAGNOSTIC TECHNIQUES; IMAGE PROCESSING; PATIENTS; PEDIATRICS; QUALITY CONTROL
- Descriptors DEC
- ANIMALS; BODY; BODY AREAS; CONTROL; MAMMALS; MAN; MEDICINE; PRIMATES; TOMOGRAPHY; VERTEBRATES