Published October 2006 | Version v1
Journal article

Response model for Kodak Biomax-MS film to x rays

  • 1. Plasma Studies Laboratory, Cornell University, Ithaca, New York 14853 (United States)
  • 2. Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623 (United States)

Description

X-ray-sensitive film is used for a variety of imaging and spectroscopic diagnostics for high-temperature plasmas. Replacement film must be found as older films are phased out of production. Biomax-MS is a 'T-grain' class of film that is proposed as a replacement for Kodak DEF and a model of its response to x rays is presented. Data from dimensional measurements of the film, x-ray transmission measurements, scanning electron microscopy micrograph images, and x-ray calibration are used to develop this sensitivity model of Biomax-MS film as a function of x-ray energy and angle of incidence. Relative response data provide a check of the applicability of this model to determine the x-ray flux from spectrum data. This detailed film characterization starts with simple mathematical models and extends them to T-grain-type film

Additional details

Identifiers

Publishing Information

Journal Title
Review of Scientific Instruments
Journal Volume
77
Journal Issue
10
Journal Page Range
p. 10F331
ISSN
0034-6748
CODEN
RSINAK

Optional Information

Notes
(c) 2006 American Institute of Physics