Radiation dose index monitoring (RDIM) systems may help identify CT dose reduction opportunities, but variability and complexity of imaging procedures make consistent dose optimization and standardization a challenge. This study aimed to investigate the feasibility to standardize and optimize CT protocols through the implementation of a Dose Excellence Program within a European healthcare network. The Dose Excellence Program consisted of a multidisciplinary team that developed standardized organizational adult CT protocols and thresholds for relevant radiation dose indices (RDIs). Baseline data were collected retrospectively from the RDIM (Phase I, 2015). Organization's protocols were implemented and monitored from the RDIM for deviations (Phase II, 2016). Following standardization, radiation dose optimization was initiated (Phase III, 2017). Data from the three most used protocols were retrospectively extracted and grouped by country for all phases. The mean number of series (RS) and RDIs were compared between phases and with organizational reference levels. A Mann-Whitney test was conducted; p < .05 was considered as significant. Data from 9588, 12638, and 6093 examinations were analyzed from General Chest, General Head, and Thorax/Abdomen/Pelvis (TAP) multiphase respectively. Overall, after Phase III, mean RS and CTDIvol p75 were below the organizational reference levels in all countries for the three protocols. The CTDIvol decreased by 45% in Switzerland (p < .00001), 32% in Turkey (p < .00001), and 28% in Switzerland (p = .0027) for General Chest, General Head, and TAP multiphase respectively. The implementation of a Dose Excellence Program within a large-scale healthcare organization allowed unifying protocols and optimizing radiation dose across countries.

Availability note (English)

Available from: http://dx.doi.org/10.1007/s00330-021-07986-8

Additional details

Identifiers

Publishing Information

Journal Title
European Radiology (Internet)
Journal Volume
31
Journal Issue
12
Journal Page Range
p. 9188-9197
ISSN
1432-1084
CODEN
EURAE3