Description

Results are presented of beam tests in which a small electromagnetic calorimeter consisting of lead tungstate crystals was exposed to 50 GeV electrons and pions. This calorimeter was backed up by the DREAM Dual-Readout calorimeter, which measures the scintillation and Cherenkov light produced in the shower development, using two different media. The signals from the crystal calorimeter were analyzed in great detail in an attempt to determine the contributions from these two types of light to the signals, event by event. This information makes it possible to eliminate the dominating source of fluctuations and thus achieve an important improvement in hadronic calorimeter performance

Availability note (English)

Available from http://dx.doi.org/10.1016/j.nima.2007.09.035

Additional details

Identifiers

DOI
10.1016/j.nima.2007.09.035;
arXiv
arXiv:0707.4021v1;
PII
S0168-9002(07)02075-X;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
584
Journal Issue
2-3
Journal Page Range
p. 273-284
ISSN
0168-9002
CODEN
NIMAER