Published June 15, 1987 | Version v1
Journal article

An electromagnetic calorimeter with scintillator strips and wavelength shifter readout

  • 1. Universidad Autonoma de Madrid (Spain)
  • 2. Siegen Univ. (Gesamthochschule) (Germany, F.R.)
  • 3. Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany, F.R.)

Description

We have built an electromagnetic calorimeter of the lead scintillator sandwich type. The dimensions of the lead plates are 20 x 60 cm2 and their thickness 6 mm. A scintillator layer consists of 12 strips, 20 x 5 cm2 and 2.5 mm thick. Each strip is read out using wavelength shifting plates at both sides. The mechanical stability of the module is provided by tie-rods and spacers. We have tested it in a 1 to 5 GeV electron beam. The influence of rods and spacers of various shapes and sizes on the uniformity of response and energy resolution is investigated. (orig.)

Additional details

Publishing Information

Journal Title
Nucl. Instrum. Methods Phys. Res., Sect. A
Journal Volume
257
Journal Issue
2
Series
Nucl. Instrum. Methods Phys. Res., Sect. A.
Journal Page Range
145-154
ISSN
0168-9002
CODEN