Hepatic steatosis assessment with 1H-spectroscopy and chemical shift imaging at 3.0 T before hepatic surgery: Reliable enough for making clinical decisions?
Creators
- 1. Department of Radiology, Medical University of Vienna (Austria)
- 2. Department of Pathology, Medical University of Vienna (Austria)
- 3. Department of Surgery, Medical University of Vienna (Austria)
- 4. Department of Radiology, KH Goettlicher Heiland and Herz-Jesu Krankenhaus, Dornbacher Strasse 20-28, 1170 Vienna (Austria)
Description
Purpose: To compare the accuracy of liver fat quantification using chemical shift imaging (CSI) and H1 MR-spectroscopy (MRS) at 3.0 T in patients undergoing liver resection. Methods: Totally 35 patients were included in this prospective IRB approved study. The histopathologically assessed liver fat was compared to the hepatic fat fractions calculated with CSI (with and without spleen correction) and MRS. Spearman's rank correlation and Fisher z-test were used for correlation analysis. Sensitivity and specificity regarding the detection of marked steatosis were calculated for the different modalities and compared using the McNemar test. Results: MRS (r = .85) and CSI with spleen correction (r = .85) showed a significantly better correlation (p = .03) with histology compared to CSI without spleen correction (r = .67). Sensitivity and specificity for the detection of marked steatosis was 100% (12/12) and 87% (20/23) for MRS and 92% (11/12) and 83% (19/23) for CSI with spleen correction (p > .12). Conclusion: For the assessment of hepatic steatosis both CSI with spleen correction and MRS at 3.0 T, show a good correlation with histology. CSI without spleen correction should not be used. Sensitivity and specificity for the detection of marked steatosis are high with both modalities. However, results that are scattered around the cut-off values are not reliable enough for clinical decisions.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.ejrad.2012.01.025Additional details
Identifiers
- DOI
- 10.1016/j.ejrad.2012.01.025;
- PII
- S0720-048X(12)00041-1;
Publishing Information
- Journal Title
- European Journal of Radiology
- Journal Volume
- 81
- Journal Issue
- 11
- Journal Page Range
- p. 2990-2995
- ISSN
- 0720-048X
- CODEN
- EJRADR
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 45027619
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- CHEMICAL SHIFT; COMPARATIVE EVALUATIONS; CORRECTIONS; CORRELATIONS; DIAGNOSIS; FATS; HISTOLOGY; HYDROGEN 1; LIVER; NMR IMAGING; PATIENTS; SENSITIVITY; SPECIFICITY; SPLEEN; SURGERY
- Descriptors DEC
- BODY; DIAGNOSTIC TECHNIQUES; DIGESTIVE SYSTEM; EVALUATION; GLANDS; HYDROGEN ISOTOPES; ISOTOPES; LIGHT NUCLEI; MEDICINE; NUCLEI; ODD-EVEN NUCLEI; ORGANS; STABLE ISOTOPES
Optional Information
- Copyright
- Copyright (c) 2012 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.