There is a newer version of the record available.

Published April 2005 | Version v1
Report

Validation of protocols for corrosion and deposit determination in pipes by radiography (by H. Fengqi)

Creators

  • 1. Nuclear Power Institute of China, Beijing (China)

Description

Chinese experts have been actively participated in the CRP project to improve radiographic methods and develop testing protocols. Besides it, some R and D works, such as gamma scanning digital system, ultrasonic pigs, real-time radioscopy and gamma computer tomography techniques are carried out. In this paper only the radiography, film image digital processing and testing procedure are reported. The tangential radiography and film processing techniques is a powerful and effective NDT method for pipe corrosion/erosion/deposit examination without remove insulator. (author)

Part of:
Development of protocols for corrosion and deposits evaluation in pipes by radiography

Additional details

Publishing Information

ISBN
92-0-102105-4
Imprint Title
Development of protocols for corrosion and deposits evaluation in pipes by radiography
Imprint Pagination
114 p.
Journal Page Range
p. 37-41
ISSN
1011-4289
Report number
IAEA-TECDOC--1445

INIS

Country of Publication
International Atomic Energy Agency (IAEA)
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
36078391
Subject category
S37: INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL CHEMISTRY;
Descriptors DEI
CORROSION; DEPOSITS; EROSION; IMAGE PROCESSING; INDUSTRIAL RADIOGRAPHY; PIPES; VALIDATION
Descriptors DEC
CHEMICAL REACTIONS; MATERIALS TESTING; NONDESTRUCTIVE TESTING; PROCESSING; TESTING; TUBES

Optional Information

Notes
3 refs, 3 figs