Dispersed-flow film boiling in rod-bundle geometry: steady-state heat-transfer data and correlation comparisons

Description

Assessment of six film boiling correlations and one single-phase vapor correlation has been made using data from 22 steady state upflow rod bundle tests (series 3.07.9). Bundle fluid conditions were calculated using energy and mass conservation considerations. Results of the steady state film boiling tests support the conclusions reached in the analysis of prior transient tests 3.03.6AR, 3.06.6B, and 3.08.6C. Comparisons between experimentally determined and correlation-predicted heat transfer coefficients, are presented

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS., PC A15/MF A01 as DE82013358.

Files

14720472.pdf

Files (68.4 MB)

Name Size Download all
md5:c8fe00fbaf72f6e42441d0eae4d202ed
68.4 MB Preview Download

Additional details

Additional titles

Augmented title (English)
PWR; BWR

Publishing Information

Imprint Pagination
345 p.
Report number
NUREG/CR--2435

Optional Information

Secondary number(s)
ORNL--5822.