Published July 15, 1995
| Version v1
Journal article
Design of a low noise, self-triggered, monolithic preamplifier dedicated to silicon trackers and X-β imaging
- 1. Strasbourg-1 Univ., 67 (France). Lab. d' Electronique et de Physique des Systemes Instrumentaux (LEPSI)
Description
A monolithic and triggerable charge amplifier has been implemented in a 1.2 μm CMOS technology. Initially developed for the LEP-DELPHI spectrometer (CERN), this architecture is also potentially useful for X and β imaging due to its noise performances (ENC=110 e- rms+10 e- rms/pf), low power consumption (Pd=1.5 mW/channel), internal triggerability and shaping time adjustability between 1 and 2 μs. (orig.)
Additional details
Publishing Information
- Journal Title
- Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
- Journal Volume
- 361
- Journal Issue
- 3
- Journal Page Range
- p. 568-573.
- ISSN
- 0168-9002
- CODEN
- NIMAER
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- Netherlands
- INIS RN
- 26077605
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Descriptors DEI
- AMPLIFIERS; IMAGE PROCESSING; NOISE; PARTICLE TRACKS; PERFORMANCE; PREAMPLIFIERS; RADIATION DETECTORS; READOUT SYSTEMS; SILICON
- Descriptors DEC
- ELECTRONIC EQUIPMENT; ELEMENTS; EQUIPMENT; MEASURING INSTRUMENTS; SEMIMETALS