Evaluation of the middle and inner ear structures: comparison of hybrid rendering, virtual endoscopy and axial 2D source images

  • 1. Dept. of Diagnostic Radiology, Klinikum Grosshadern, University of Munich, Munich (Germany)
  • 2. Tuebingen Univ. (Germany). Abt. fuer Radiologische Diagnostik
  • 3. Department of Psychiatry, Klinikum Innenstadt, University of Munich, Munich (Germany)
  • 4. Department of Otorhinolaryngology, Head and Neck Surgery, Klinikum Grosshadern, University of Munich, Munich (Germany)
  • 5. Department of Medical Informatics and Health System Research, GSF-National Research Center for Environment and Health, Neuherberg (Germany)

Description

Recent developments in 3D reconstructions can enhance the quality and diagnostic value of axial 2D image data sets with direct benefits for clinical practice. To show the possible advantages of a hybrid rendering method [color-coded 3D shaded-surface display (SSD)- and volume rendering method] with the possibility of virtual endoscopy we have specifically highlighted the use in relation to the middle and inner ear structures. We examined 12 patients with both normal findings and postoperative changes, using image data sets from high-resolution spiral computed tomography (HRSCT). The middle and inner ear was segmented using an interactive threshold interval density volume-growing method and visualized with a color-coded SSD rendering method. The temporal bone was visualized using a transparent volume rendering method. The 3D- and virtual reconstructions were compared with the axial 2D source images. The evaluated middle and inner ear structures could be seen in their complete form and correct topographical relationship, and the 3D- and virtual reconstructions indicated an improved representation and spatial orientation of these structures. A hybrid and virtual endoscopic method could add information and improve the value of imaging in the diagnosis and management of patients with middle or inner ear diseases making the understanding and interpretation of axial 2D CT image data sets easier. The introduction of an improved rendering algorithm aids radiological diagnostics, medical education, surgical planning, surgical training, and postoperative assessment. (orig.)

Additional details

Publishing Information

Journal Title
European Radiology
Journal Volume
9
Journal Issue
9
Journal Page Range
p. 1851-1858
ISSN
0938-7994
CODEN
EURAE3

INIS

Country of Publication
Germany
Country of Input or Organization
Germany
INIS RN
31002840
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
AUDITORY ORGANS; BIOMEDICAL RADIOGRAPHY; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; IMAGES
Descriptors DEC
BODY; DIAGNOSTIC TECHNIQUES; MEDICINE; ORGANS; SENSE ORGANS; TOMOGRAPHY

Optional Information

Notes
With 2 figs., 1 tab., 16 refs.