Experimental investigation of hydrocarbon mixtures to replace HFC-134a in an automotive air conditioning system

  • 1. Fluid Mechanics, Thermal Engineering and Multiphase Flow Research Lab. (FUTURE), Department of Mechanical Engineering, King Mongkut's University of Technology Thonburi, Bangmod, Bangkok 10140 (Thailand)
  • 2. Department of Mechanical Technology Education, King Mongkut's University of Technology Thonburi, Bangmod, Bangkok 10140 (Thailand)

Description

This paper presents an experimental study on the application of hydrocarbon mixtures to replace HFC-134a in automotive air conditioners. The hydrocarbons investigated are propane (R290), butane (R600) and isobutane (R600a). The measured data are obtained from an automotive air conditioning test facility utilizing HFC-134a as the refrigerant. The air conditioner, with a capacity of 3.5 kW driven by a Diesel engine, is charged and tested with four different ratios of hydrocarbon mixtures. The experiments are conducted at the same surrounding conditions. The temperature and pressure of the refrigerant at every major position in the refrigerant loop, the temperature, flow rate and humidity of air, torque and engine speed are recorded and analyzed. The parameters investigated are the refrigeration capacity, the compressor power and the coefficient of performance (COP). The results show that propane/butane/isobutane: 50%/40%/10% is the most appropriate alternative refrigerant to replace HFC-134a, having the best performance of all the hydrocarbon mixtures investigated

Additional details

Identifiers

DOI
10.1016/j.enconman.2005.04.013;
PII
S0196-8904(05)00203-7;

Publishing Information

Journal Title
Energy Conversion and Management
Journal Volume
47
Journal Issue
11-12
Journal Page Range
p. 1644-1659