Measurement of rf accelerator cavity field levels at high power from x-ray emissions

  • 1. Los Alamos National Lab., NM (United States)

Description

Energy spectroscopy measurements of x-rays from rf structures at high power provide an independent method of finding accelerating-gap voltages in the multiple-cell accelerating structures. An x-ray detector is used to measure the energy of the emitted x-rays; and the high-energy endpoint of the energy spectrum histogram corresponds with the peak-gap voltage in the rf structure. The x-ray measurements are used to provide a calibration relating peak-gap voltage to rf structure field sampling probes. The analyzed x-ray data has been compared to theoretical SUPERFISH and MAFIA3D predictions and to beam-dynamics data for the multiple-cell structures. Information about this diagnostic technique and its value for verifying accelerator modeling codes is presented

Additional details

Publishing Information

Imprint Title
Proceedings of the 1990 linear accelerator conference
Imprint Pagination
845 p.
Journal Page Range
p. 219-222.
Report number
LA--12004-C

Conference

Title
1990 Linear accelerator conference.
Dates
9-14 Sep 1990.
Place
Albuquerque, NM (United States).

Optional Information

Secondary number(s)
CONF-9009123--.