Published July 19, 2000 | Version v1
Report Open

NEUTRON ALGORITHM VERIFICATION TESTING

Description

Active well coincidence counter assays have been performed on uranium metal highly enriched in 235U. The data obtained in the present program, together with highly enriched uranium (HEU) metal data obtained in other programs, have been analyzed using two approaches, the standard approach and an alternative approach developed at BNL. Analysis of the data with the standard approach revealed that the form of the relationship between the measured reals and the 235U mass varied, being sometimes linear and sometimes a second-order polynomial. In contrast, application of the BNL algorithm, which takes into consideration the totals, consistently yielded linear relationships between the totals-corrected reals and the 235U mass. The constants in these linear relationships varied with geometric configuration and level of enrichment. This indicates that, when the BNL algorithm is used, calibration curves can be established with fewer data points and with more certainty than if a standard algorithm is used. However, this potential advantage has only been established for assays of HEU metal. In addition, the method is sensitive to the stability of natural background in the measurement facility

Availability note (English)

Available from INIS in electronic form; Also available from OSTI as DE00759052; PURL: https://www.osti.gov/servlets/purl/759052-EXz2HQ/native/

Files

32003040.pdf

Files (168.9 kB)

Name Size Download all
md5:f5e41a8fa9290afe243510e1c457602a
168.9 kB Preview Download

Additional details

Publishing Information

Imprint Pagination
9 p.
Report number
BNL--67165

Conference

Title
41. annual meeting of the Institute of Nuclear Materials Management
Dates
16-20 Jul 2000
Place
New Orleans, LA (United States)

Optional Information

Contract/Grant/Project number
AC02-98CH10886
Funding organization
OFFICE OF SAFEGUARDS AND SECURITY/DOE (United States)
Secondary number(s)
GD--0604020