Dose evaluation of multi-slice CT for different parameters in chest examinations using TLD method
Creators
- 1. Department of Radiological Technology, Yuanpei University, Hsinchu, Taiwan (China)
- 2. Department of Diagnostic Radiology, Taipei Medical University Hospital, Taipei, Taiwan (China)
- 3. Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu, Taiwan (China)
- 4. Nuclear Science Technology and Development Center, National Tsing Hua University, Hsinchu, Taiwan (China)
Description
In radiodiagnosis, optimization is defined as a method of reducing the patient-absorbed doses without affecting image quality. In this study, we aimed to determine the parameters of a multi-slice CT (MSCT) scanner (LightSpeed VCT 64; General Electric) that ensure the least organ dose with the best image quality (i.e., optimization) for chest examinations, which are the most frequently used radio diagnostic investigations. Organ doses of an anthropomorphic phantom were measured during MSCT chest scans by using GR-100 (LiF: Mg, Ti) thermo-luminescent dosimeters (TLDs) attached to various parts of the organs. The accumulated equivalent doses were calculated to evaluate the radiation risk to sensitive organs by using different scan conditions and measuring the absorbed doses, because different scan parameters (e.g., pitch, tube current, scan type, etc.) may affect the dose contribution to these organs. By means of the radiation and tissue weighting factors recommended in the International Commission on Radiological Protection (ICRP) 103 report, the effective dose was then estimated. The pitch value and tube current were the main parameters affecting the organ doses of the phantom: increase in the pitch value and reduction of the tube current decreased the absorbed doses without impacting the image resolution and diagnostic information. Consequently, radiologists can establish an optimization protocol in MSCT and acquire high-resolution images with adequate diagnostic information while using the lowest exposure dose for chest examinations.
Availability note (English)
Available from http://dx.doi.org/10.1016/j.radmeas.2009.12.043Additional details
Identifiers
- DOI
- 10.1016/j.radmeas.2009.12.043;
- PII
- S1350-4487(09)00410-7;
Publishing Information
- Journal Title
- Radiation Measurements
- Journal Volume
- 45
- Journal Issue
- 3-6
- Journal Page Range
- p. 701-703
- ISSN
- 1350-4487
- CODEN
- RMEAEP
Conference
- Title
- 7. European conference on luminescent detectors and transformers of ionizing radiation
- Acronym
- LUMDETR 2009
- Dates
- 8-13 Jul 2009
- Place
- Krakow (Poland)
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 42009093
- Subject category
- S61: RADIATION PROTECTION AND DOSIMETRY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CHEST; COMPUTERIZED TOMOGRAPHY; DOSE EQUIVALENTS; OPTIMIZATION; PHANTOMS; RADIATION DOSES; THERMOLUMINESCENT DOSEMETERS; THERMOLUMINESCENT DOSIMETRY
- Descriptors DEC
- BODY; DIAGNOSTIC TECHNIQUES; DOSEMETERS; DOSES; DOSIMETRY; LUMINESCENT DOSEMETERS; MEASURING INSTRUMENTS; MOCKUP; STRUCTURAL MODELS; TOMOGRAPHY
Optional Information
- Copyright
- Copyright (c) 2010 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.