Published March 2010 | Version v1
Journal article

Dose evaluation of multi-slice CT for different parameters in chest examinations using TLD method

  • 1. Department of Radiological Technology, Yuanpei University, Hsinchu, Taiwan (China)
  • 2. Department of Diagnostic Radiology, Taipei Medical University Hospital, Taipei, Taiwan (China)
  • 3. Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, Hsinchu, Taiwan (China)
  • 4. Nuclear Science Technology and Development Center, National Tsing Hua University, Hsinchu, Taiwan (China)

Description

In radiodiagnosis, optimization is defined as a method of reducing the patient-absorbed doses without affecting image quality. In this study, we aimed to determine the parameters of a multi-slice CT (MSCT) scanner (LightSpeed VCT 64; General Electric) that ensure the least organ dose with the best image quality (i.e., optimization) for chest examinations, which are the most frequently used radio diagnostic investigations. Organ doses of an anthropomorphic phantom were measured during MSCT chest scans by using GR-100 (LiF: Mg, Ti) thermo-luminescent dosimeters (TLDs) attached to various parts of the organs. The accumulated equivalent doses were calculated to evaluate the radiation risk to sensitive organs by using different scan conditions and measuring the absorbed doses, because different scan parameters (e.g., pitch, tube current, scan type, etc.) may affect the dose contribution to these organs. By means of the radiation and tissue weighting factors recommended in the International Commission on Radiological Protection (ICRP) 103 report, the effective dose was then estimated. The pitch value and tube current were the main parameters affecting the organ doses of the phantom: increase in the pitch value and reduction of the tube current decreased the absorbed doses without impacting the image resolution and diagnostic information. Consequently, radiologists can establish an optimization protocol in MSCT and acquire high-resolution images with adequate diagnostic information while using the lowest exposure dose for chest examinations.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.radmeas.2009.12.043

Additional details

Identifiers

DOI
10.1016/j.radmeas.2009.12.043;
PII
S1350-4487(09)00410-7;

Publishing Information

Journal Title
Radiation Measurements
Journal Volume
45
Journal Issue
3-6
Journal Page Range
p. 701-703
ISSN
1350-4487
CODEN
RMEAEP

Conference

Title
7. European conference on luminescent detectors and transformers of ionizing radiation
Acronym
LUMDETR 2009
Dates
8-13 Jul 2009
Place
Krakow (Poland)

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
42009093
Subject category
S61: RADIATION PROTECTION AND DOSIMETRY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CHEST; COMPUTERIZED TOMOGRAPHY; DOSE EQUIVALENTS; OPTIMIZATION; PHANTOMS; RADIATION DOSES; THERMOLUMINESCENT DOSEMETERS; THERMOLUMINESCENT DOSIMETRY
Descriptors DEC
BODY; DIAGNOSTIC TECHNIQUES; DOSEMETERS; DOSES; DOSIMETRY; LUMINESCENT DOSEMETERS; MEASURING INSTRUMENTS; MOCKUP; STRUCTURAL MODELS; TOMOGRAPHY

Optional Information

Copyright
Copyright (c) 2010 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.