Use of a cadmium telluride detector in a new tiny personal radiation chirper

Description

By use of a CdTe crystal coupled to newly designed, low power electronics, we have developed a new personal radiation chirper that is superior to existing instruments. The device emits audible chirps or beeps at a rate proportional to the photon radiation exposure to the wearer. The device is small (6.2 cm high by 3.2 cm wide by 1.7 cm thick) and of low mass (50 grams) and is made to be clipped to the shirt collar of the wearer. The instrument has long continuous-use battery life and is sensitive over a large photon energy and exposure rate span

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS., PC A02/MF A01.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
4 p.
Report number
LA-UR--78-2697

Conference

Title
IEEE nuclear science symposium.
Dates
18 - 20 Oct 1978.
Place
Washington, DC, USA.

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
10449890
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
CDTE SEMICONDUCTOR DETECTORS; PERFORMANCE; PERSONNEL DOSIMETRY; SENSITIVITY
Descriptors DEC
DOSIMETRY; MEASURING INSTRUMENTS; RADIATION DETECTORS; SEMICONDUCTOR DETECTORS

Optional Information

Secondary number(s)
CONF-781033--20.