Field quality measurements of Fermilab Nb3Sn common coil dipole model

Description

A short model of single-layer Nb3Sn common coil magnet has been fabricated and is being tested at Fermilab. This paper summarizes results of magnetic measurements in this model. The geometrical harmonics, coil magnetization and iron saturation effects, ramp-rate dependence, field decay and the ''snap-back'' effect at injection are presented

Availability note (English)

Available from PURL: https://www.osti.gov/servlets/purl/817268-pXX0FO/native/

Additional details

Publishing Information

Imprint Pagination
116 Kilobytes
Report number
FERMILAB-Conf--03/319-E

Conference

Title
18. International Conference on Magnet Technology
Dates
20-24 Oct 2003
Place
Morioka (Japan)

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
35002558
Subject category
S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
BEAM INJECTION; FERMILAB; IRON; MAGNET COILS; MAGNETIC DIPOLES; MAGNETIZATION; MEASURING METHODS; NIOBIUM COMPOUNDS; PERFORMANCE TESTING; TIN COMPOUNDS
Descriptors DEC
DIPOLES; ELECTRIC COILS; ELECTRICAL EQUIPMENT; ELEMENTS; EQUIPMENT; METALS; MULTIPOLES; NATIONAL ORGANIZATIONS; REFRACTORY METAL COMPOUNDS; TESTING; TRANSITION ELEMENT COMPOUNDS; TRANSITION ELEMENTS; US DOE; US ORGANIZATIONS

Optional Information

Contract/Grant/Project number
AC02-76CH03000
Funding organization