Published September 18, 1987 | Version v1
Report Open

RELAP 5 Simulations of a hypothetical LOCA in Ringhals 2

Description

RELAP5 simulations of a hypothetical LOCA in Ringhals 2 were conducted in order to determine the sensitivity of the calculated peak cladding temperature (PCT) to Appendix K requirements. The PCT was most sensitive to the assumed model decay heat: Changing from the 1979 ANS Standard to 1.2 times the 1973 Standard increased the PCT by 70 to 100K. After decay heat, the two parameters which affected the PCT the most were steam generator heat transfer and heat transfer lockout. The PCT was not sensitive to the assumed pump rotor condition (locked vs coasting); nor was it sensitive to a modest amount (5 to 10%) of steam generator tube plugging. (author)

Availability note (English)

MF available from INIS under the Report Number.

Files

20019277.pdf

Files (1.4 MB)

Name Size Download all
md5:b7e81aadcd22c5e49727dd2410c26d32
1.4 MB Preview Download

Additional details

Publishing Information

Imprint Pagination
71 p.
Report number
SKI--87089

Optional Information

Contract/Grant/Project number
Project SKI-13.3-991/85-87089
Secondary number(s)
STUDSVIK-NP--87-105.