20CrMnTi wire rod can be used to manufacture the anchorage clamp plate. In the normal production, the test results show that the hardness of anchorage clamp plate is nonuniform. In this paper, the chemical composition, microstructure, grain size of clamp plate billet and the microstructure, hardness of the finished clamp plate product were studied and analyzed. The results show that improper heat treatment technic causes nonuniform hardness for anchorage clamp plate. (paper)
Availability note (English)
Available from http://dx.doi.org/10.1088/1757-899X/230/1/012028Additional details
Identifiers
Publishing Information
- Journal Title
- IOP Conference Series. Materials Science and Engineering (Online)
- Journal Volume
- 230
- Journal Issue
- 1
- Journal Page Range
- [6 p.]
- ISSN
- 1757-899X
Conference
- Title
- International conference on materials sciences and nanomaterials
- Dates
- 14 Jul - 16 Aug 2017
- Place
- Barcelona (Spain)
INIS
- Country of Publication
- United Kingdom
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 49094909
- Subject category
- S36: MATERIALS SCIENCE;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- AFTER-HEAT; CHEMICAL COMPOSITION; CHROMIUM COMPOUNDS; GRAIN SIZE; HARDNESS; HEAT TREATMENTS; MANGANESE COMPOUNDS; RODS; TITANIUM COMPOUNDS; WIRES
- Descriptors DEC
- MECHANICAL PROPERTIES; MICROSTRUCTURE; SIZE; TRANSITION ELEMENT COMPOUNDS