Published 1987 | Version v1
Book

Simple shielding design method from medical and industrial electron accelerators

  • 1. Cyclotron and Radioisotope Center, Tohoku Univ., Aoba, Aramaki, Sendai 980

Description

The neutron leakage from medical and industrial electron accelerators has become an important problem and its detection and shielding is being performed in their facilities. This study provides a new simple method of design calculation for neutron shielding of these electron accelerator facilities by dividing into the following five steps; 1) neutron dose distribution in the irradiation room, 2) neutron attenuation through the wall and the door between the irradiation room and maze, 3) neutron dose distribution in the maze, 4) neutron and secondary photon attenuation through the door at the maze exit, 5) neutron leakage outside the facility - skyshine. The accuracy of new simple method of design calculation for neutron shielding in medical and industrial accelerator facilities is investigated by comparing with the measured data in the actual facilities. From the comparison of measured and calculated neutron dose equivalents, it was confirmed that this simple design method has sufficiently good accuracy

Additional details

Publishing Information

Publisher
National Technical Information Service.
Imprint Place
Springfield, VA (USA)
Imprint Title
Health physics of radiation generating machines 20th midyear topical symposium
Journal Page Range
p. 133-140.

Conference

Title
health physics of radiation-producing machines.
Acronym
20. midyear topical symposium of the Health Physics Society
Dates
8-12 Feb 1987.
Place
Reno, NV (USA).