The gamma radiation calibration curve of 60 Co is used which was generated in the ININ Laboratory of Biology to calculate the exposure dose of two workers whose dosemeters marked values above of the limit allowed. The analysis indicates that in a first case, the aberrations frequency corresponded to the basal value, therefore there is not over exposure. The aberrations frequency of the second case is lightly above to the basal value and therefore the probability favors to what the physical dosimetry indicates. (Author)